Zhangqiu, Jinan, Shandong, China Sales 0531-83738299

How to read a construction hoist load chart

2026-11-16 09:00:00 Technical Q&A

Most hoist enquiries arrive with a single number: "we need two tonnes". That number is valid for one column of one chart. A construction hoist load chart is a matrix — cage load, mast height, tie-in spacing, wind — and the limit that governs the site is usually lower than the headline figure.

What the chart actually lists

A properly issued SC-series chart carries four separate blocks, and they are not interchangeable:

  • Rated load per cage — 2,000 kg for SC200/200, and that figure already includes the operator, tools and any cage-mounted equipment.
  • Persons — 12 persons at 80 kg each, or 2,000 kg of material. You never add passengers to a full material load.
  • Lifting height — the load is derated above a stated mast height, typically 150 m or 200 m depending on mast section and tie-in spacing.
  • Wind speed — operation stops at 20 m/s; erection and dismantling stop at 13 m/s.

Why height changes the limit

A 650 × 650 mast is a column under compression, and its capacity falls as free standing length rises. The chart compensates in two ways: tie-ins are added at shorter intervals, and the permitted cage load is reduced above each height band. On a 180 m job the same SC200/200 that lifts 2,000 kg at 60 m may be limited well below that at the top landing, because the mast section between two tie-ins is longer in terms of load path, not just metres.

This is why a chart copied from a catalogue is not a project chart. Jib length has an exact parallel on tower cranes: the number at the tip is what governs the lift, not the number at the root.

The comparison that matters at the gate

ConditionRated load per cagePersonsSpeed
SC200/200, 100 m, tie-in 9 m2,000 kg1234 m/min
SC200/200, 180 m, tie-in 6 m2,000 kg1234 m/min
SC200/200 above 200 mdual-drive configuration120–63 m/min
SC100/100, 150 m1,000 kg1234 m/min

What to check before you accept a chart

  • The chart states the mast height and tie-in spacing it applies to, not only the model.
  • Persons and kilograms are separate rows — a chart that merges them cannot be used for a passenger hoist.
  • Wind limits appear on the chart, not only in the manual.
  • The anti-fall device rating (SAJ40 for the SC series) is stated with its calibration date.

Frequently asked

Can I run 2,000 kg at any height? Only within the height band the chart covers. Above it, either the tie-in spacing shortens or the load is derated.

Are 12 persons equal to 2,000 kg? No. Twelve persons at 80 kg is 960 kg; the cage still has mass capacity left, but you do not load material on top of a full passenger load.

Who issues the project chart? The manufacturer, against the actual mast height, tie-in plan and wind region. Catalogue charts are for selection only.

Related: SC200/200 standard hoist · SC100/100 dual cage · SAJ40 anti-fall device

← Back to list Request a quote
SC200/200 vs SC100/100: which hoist for 40 floors

Send the site data, get a configuration and a price

Building height, required payload and power supply are enough for us to come back with a model, a drawing and a delivered price within one working day.

15688868277